FEATURES
|
- Compact design, ABS housing
- Up to 12,500 punch storage capacity
- For Access Control 550 Employee Database can be stored with Employee Name
- Up to 8 digit Card Number
- 16 x 2 LCD display for Date, Time, Employee Name, Card Number,
Scrolling Message etc.
- For Access Control Support for Lock Output, Door Monitoring and facility of
External Reader OR Switch for Exit
- Programmable IN / OUT setting
- Programmable 5 different Reason Cards
- Networking through RS 485 / Modem / TCP/IP
- Up to 32 terminal Networking
- Switch Mode Power Supply (SMPS)
|
OPTIONAL FEATURES
|
- External Reader: with 16 x 2 LCD Display for separate IN / OUT or Access Control
- UPS for full operation
- Networking through Modem for transferring data from remote locations
- Keypad : 4 x 4 - Numeric and Function Keys
- Modem Connectivity / TCP/IP
|
SOFTWARE
|
- Proven software for all needs - for less than 10 employees to more than 5000 employees
- User friendly Transfer and MIS Software
- Different software for Offices (without night shift) and Factories having night shift
- Customized payroll available with legal forms (Optional)
|
TECHNICAL SPECIFICATION
|
| Card Reader | Barcode infra red slot reader (3 of 9 code) |
| Card Number | Up to 8 Digits |
| Display | Date, Time, Card Number, Employee Name,
Scrolling Message etc. |
| | Display - Type | 16 X 2 LCD with Backlit |
| Indicators | 3 LED for Power ON (Red), Communication
ON (Yellow) and Card Read OK (Green) |
| Battery Back-up | For Data and RTC - 1 year |
| Communication | RS 232 / RS485 / Modem / TCP/IP |
| Networking | Up to 32 Terminals |
| Buzzer | Card Read OK / Error |
| Memory | 64K NVRAM, up to 12,500 punches & Emp. Database |
| Reason Card | For On Duty (User definable 5 cards) |
| Weight | 300 grams (Approximate) |
| Size (H x W x D) | 144 mm x 130 mm x 35 mm |
| Mounting | Wall Mounting |
| Operating Environment | Dust free - Normal gate environment |
| Operating
Voltage | 9
volts DC regulated |
| Output | One
Relay (with NO & NC Contact) |
| Input | Door
Switch for Activating Relay & IN / OUT
status setting |
|
OPTIONAL
|
| Keypad | Numeric & Function keys |
| UPS | For full operation |
| External Reader | For separate IN / OUT Setting OR for Access Control |
|